Extreme
Parameters guaranteed for the salt spray test:
Chamber
volume
1x1x1
mt
Test
temperature
+25
÷ +55°C
Water
pH
3
÷ 8 Ph
Precipitation
level
0
÷
30 ml/h x m3
Degree
of salinity
3
÷ 10 %
All test parameters are monitored with such instruments as pH
meters, conductivity meters, thermometers, and others required
by the reference standards, that are on their end based on certified
solutions or company primary instruments, certified by SIT.
Test
standards that ELET.CA is capable of performing at its laboratories:
Standard
Description
ASTM
B 117-73
Standard
Test Method of Salt Spray (FOG) Testing
ASTM
B 117-90
Standard
Test Method of Salt Spray (FOG) Testing
FINABEL
2.C.10 - 41.3
Resistance
au Brouillard Salin
FINABEL
17.E. 1 - XIV
Essai
de Brouillard Salin
MIL
STD 810C - Method 509.1
Saltfog
UNI
ISO 9227
Saltfog
Corrosion Test
The main differences among the test standards are:
-
concentration of the saline solution
- temperature inside the chamber
- precipitation level
Other
tests can be run, meeting the parameters guaranteed by the
test center