| Radiated
measurements Pre Compliance |
|
| Radiated
Emission Tests |
|
|
Test
performed, by monitoring, in the desired frequency range,
the electromagnetic field values, radiated by the item, when
performing its functions. The item is of course placed inside
the Tem cell and operated at its nominal voltage supply.
Hereunder
find a summary of the extreme parameters that our center can
guarantee for the measurement of radiated emission:
| Frequency
(MHz) |
from
0 to 1000 |
| Item
Dimensions (mm) |
150
x 100 x 150 |
|
Item Power Supply |
Vdc |
|
|
| |
| Test
of radiated susceptibility |
|
|
Test
performed by irradiating the test item with a perturbation
of different levels (V/m), depending on the standard and the
required severity, and verifying its functioning.
The
item is of course placed inside the Tem cell and operated
at its nominal voltage supply.
Hereunder
find a summary of the extreme parameters that our center can
guarantee for the measurement of radiated susceptibility
| Frequency
(MHz) |
from
0 to 1000 |
| Item
Dimensions (mm) |
150
x 100 x 150 |
| Electric
Field (V/m) |
15 |
| Item
Power Supply |
Vdc |
|
|
| |
| Main
standards |
|
|
Other
test procedures are available at our center, always inside
the ranges of frequency, power and dimensions listed above.
The laboratory is also capable of providing problem solving
support, based on our knowledge, for whatever comes out during
the tests.
| Standard |
MIL
STD 461 |
| Procedure |
UM
05 |
| Description |
Radiated
Emission from 150 KHz to 400 MHz |
| Level |
10
(V/m) |
|
|
| |
| Instrumentation
used for radiated measurements: |
|
| Tem
Cell 0 1Ghz |
| Spectrum
Analyzer 9Khz -3 Ghz |
|
Amplifier Rf 9Khz .... 1Ghz-1,5W |
| Generator
Rf 9Khz ÷ 2,7 Ghz
|
|
Feed TrueSet |
|
|
| |
| Conducted
measurements Pre compliance |
|
| Tests
of conducted emissions |
|
|
Test
performed by monitoring, inside the desired frequency range,
on the connectors of the generator the values of voltage and
current that the item generates towards the external world.
The
item will be connected through a Feed-True, positioned on
the ground plane and operated at its nominal voltage, as per
the applicable standards.
Hereunder
find a summary of the extreme parameters that our center can
guarantee for the measurement of conducted emissions:
| Frequency
(MHz) |
from
0 to 400 |
| Power
Item (W) |
200 |
| Item
Power Supply |
Vdc |
|
|
| |
| Test
of conducted susceptibility |
|
|
Test
performed by feeding a perturbation signal of different levels
(Vpp) into the supply connectors, following the standards
and the required severity, and then verifying its functioning.
The
item will be connected through a Feed-True, positioned on
the ground plane and operated at its nominal voltage, as per
the applicable standards.
Hereunder
find a summary of the extreme parameters that our center can
guarantee for the measurement of conducted susceptibility:
| Frequency
(MHz) |
from
0 to 400 |
| Power
Item (W) |
200 |
| Item
Power Supply |
Vdc |
|
|
| |
| Main
standards |
|
| Standard |
MIL
STD 461 - 462 |
| Procedure |
CE
03 |
| Description |
Conducted
Emissions from 20 KHz to 50 MHz |
| Standard |
MIL
STD 461 - 462 |
| Procedure |
CS
01 |
| Description |
Conducted
Susceptibility from 30 Hz to 50 MHz |
| Standard |
MIL
STD 461 - 462 |
| Procedure |
CS
02 |
| Description |
Conducted
Susceptibility from 50 Hz to 400 MHz |
Other
test procedures are available at our center, always inside the
ranges of frequency and power guaranteed by the Center itself.
The laboratory offers problem solving support, based on our
knowledge, for whatever comes out during the test. |
|
| |
| |
| Instrumentation
used for conducted measurements: |
|
| Spectrum
Analyzer 9Khz ... 3 Ghz |
|
Amplifier Rf 9Khz ... 1Ghz 1,5W |
| Generator
Rf 9Khz ÷ 2,7 Ghz |
| Feed
True Set |
|
| |
|