Radiated measurements Pre Compliance
Radiated Emission Tests  

Test performed, by monitoring, in the desired frequency range, the electromagnetic field values, radiated by the item, when performing its functions. The item is of course placed inside the Tem cell and operated at its nominal voltage supply.

Hereunder find a summary of the extreme parameters that our center can guarantee for the measurement of radiated emission:

Frequency (MHz) from 0 to 1000
Item Dimensions (mm) 150 x 100 x 150
Item Power Supply Vdc
 
Test of radiated susceptibility  

Test performed by irradiating the test item with a perturbation of different levels (V/m), depending on the standard and the required severity, and verifying its functioning.

The item is of course placed inside the Tem cell and operated at its nominal voltage supply.

Hereunder find a summary of the extreme parameters that our center can guarantee for the measurement of radiated susceptibility

Frequency (MHz) from 0 to 1000
Item Dimensions (mm) 150 x 100 x 150
Electric Field (V/m) 15
Item Power Supply Vdc
 
Main standards    

Other test procedures are available at our center, always inside the ranges of frequency, power and dimensions listed above. The laboratory is also capable of providing problem solving support, based on our knowledge, for whatever comes out during the tests.

Standard MIL STD 461
Procedure UM 05
Description Radiated Emission from 150 KHz to 400 MHz
Level 10 (V/m)
 
Instrumentation used for radiated measurements:  

Tem Cell 0 1Ghz
Spectrum Analyzer 9Khz -3 Ghz
Amplifier Rf 9Khz .... 1Ghz-1,5W
Generator Rf 9Khz ÷ 2,7 Ghz
Feed TrueSet
 
Conducted measurements Pre compliance
Tests of conducted emissions  

Test performed by monitoring, inside the desired frequency range, on the connectors of the generator the values of voltage and current that the item generates towards the external world.

The item will be connected through a Feed-True, positioned on the ground plane and operated at its nominal voltage, as per the applicable standards.

Hereunder find a summary of the extreme parameters that our center can guarantee for the measurement of conducted emissions:

Frequency (MHz) from 0 to 400
Power Item (W) 200
Item Power Supply Vdc
 
Test of conducted susceptibility  

Test performed by feeding a perturbation signal of different levels (Vpp) into the supply connectors, following the standards and the required severity, and then verifying its functioning.

The item will be connected through a Feed-True, positioned on the ground plane and operated at its nominal voltage, as per the applicable standards.

Hereunder find a summary of the extreme parameters that our center can guarantee for the measurement of conducted susceptibility:

Frequency (MHz) from 0 to 400
Power Item (W) 200
Item Power Supply Vdc
 
Main standards  

Standard MIL STD 461 - 462
Procedure CE 03
Description Conducted Emissions from 20 KHz to 50 MHz

Standard MIL STD 461 - 462
Procedure CS 01
Description Conducted Susceptibility from 30 Hz to 50 MHz

Standard MIL STD 461 - 462
Procedure CS 02
Description Conducted Susceptibility from 50 Hz to 400 MHz

Other test procedures are available at our center, always inside the ranges of frequency and power guaranteed by the Center itself. The laboratory offers problem solving support, based on our knowledge, for whatever comes out during the test.
 
 
Instrumentation used for conducted measurements:  
Spectrum Analyzer 9Khz ... 3 Ghz
Amplifier Rf 9Khz ... 1Ghz 1,5W
Generator Rf 9Khz ÷ 2,7 Ghz
Feed True Set